removed from the base, the plate loosened, and the levelling bolts re-adjusted until a
level installation is attained.
9.
Slide the base collar down to the floor, and draw a line around the circumference of the
pedestal at the top of the collar, using the top of the collar as a guide. Slide the collar
back up the pedestal.
10.
Apply a bead of silicone sealer to the circumference of the pedestal, at the line, and also
to the bottom rim of the collar. Slide the collar down the pedestal and press it tightly to the
floor. The silicone sealer will create a seal where the collar meets the pedestal, and
where the collar meets the floor.
SERVICE CONNECTIONS
Install service connections as required. Locations and other data are shown on the specification
sheet.
STEAM
All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and
inspected for dirt and debris before final connection to the kettle are made.
Check the rating plate for the maximum steam pressure that your kettle is rated for. If the steam
supply pressure exceeds the rated pressure, a pressure reducing valve is required. The steam
inlet is at the right side of the kettle, as seen from the front.
CONDENSATE
A steam condensate trap must be plumbed to a drain, using minimum 1/2" NPT plumbing. The
condensate line is limited to a maximum rise of 10 feet in order for the steam pressure to
adequately force the condensate through the plumbing. Any higher rise requires a pump.
If the steam boiler to which this kettle is installed has a condensate return (closed loop system), a
1/2" steam strainer, a 1/2" steam trap, and a 1/2" check valve must be installed on the output
(condensate) side of the kettle.
FOR POWER TILT UNITS ONLY
NOTE: Ensure the electrical supply matches the kettle's requirements as stated on the rating
label.
This kettle is built to comply with CE standards. Many local codes exist, and it is the responsibility
of the owner and installer to comply with these codes.
NOTE: Maximum voltage for LVD is 440 volts for CE marked appliances.