44. Never leave the steam generator switched on or in operation if there is no water in the tank.
45. After each use, turn off the switch on the steam generator.
46. Only one the unit has cooled down after use, wipe down the outside of the steam generator with a damp cloth.
47. Regularly clean the steam nozzle with water and dry.
WARNING DO NOT touch the steam generator when in use as this reaches high temperatures.
48. DO NOT immerse the generator in order to prevent the infiltration of liquids
USE ON ESCALATORS
1.
Ensure the machine is positioned at the bottom of the escalator with the escalator moving towards the operator.
BRUSH IDENTIFICATION
Red, Blue, White and Yellow brush buttons are packed with the machine. Simply plug the buttons into the hole in the brush as
shown. Clear identification, by colour coding, helps prevent cross contamination.
TRANSPORTING THE MACHINE
•
Take extreme care when moving the machine up or down steps or stairs.
•
Incorrect lifting techniques may result in personal injury. We advise that the manual handling regulations are followed.
•
Carefully wrap the power cord and store in a dry indoor location.
•
Do not expose the machine to rain or moisture.
•
When transporting the machine ensure that all components, tanks and removable parts are securely fastened, and that the
power cord and plug are not trailing.
•
Do not lift or transport the machine whilst containing liquid as this will add considerably to the weight.
•
When transporting the machine the handle should be locked in the upright position.
•
Optional transport trolley available – see accessories.
STORAGE
•
Always switch off, empty, wipe down and dry the machine after use.
•
Both the solution and recovery tanks should be emptied and flushed out with clean water to ensure the seals and pumps are
free from any cleaning detergents.
•
Store the machine in a dry indoor area only.
•
Wrap the power cord around the cable winder ensuring that the plug is not trailing on the floor.
MAINTENANCE
WARNING - Before undertaking maintenance operations or adjustments switch off machine and unplug from the
electricity supply.
IMPORTANT – All other servicing and repairs should only be performed by a Truvox engineer or Authorised Service Agent.
IMPORTANT – Should the machine fail to operate please refer to the fault diagnosis section in the back of this instruction manual.
If the problem / remedy is not listed, please contact Truvox Customer Service Department for rapid attention.
The machine requires minimum maintenance apart from the following checks by the operator prior to use:
•
Body of the machine - Clean with a damp cloth.
•
Power cord - regularly inspect sheath, plug and cord anchorage for damage or loose connection. Only replace the power
cord with the type specified in these instructions.
•
Brushes - For maximum life, wash the brushes regularly. Ensure machine is in Transport mode when not in use. Store
additional brushes in a vertical position to avoid bending of bristles. Check for permanent bending of bristles in a particular
direction. This may occur if the machine is operated for several days without removing the brushes, which is not
recommended. If this occurs, reverse the brush so that the bent bristles are automatically straightened.
•
Wiper Blade - After years of use the wiper blade may wear. If this occurs the water collection performance will decrease. It
should be replaced by an authorised service agent.
•
Solution feed filter - The filter prevents clogging of the spray nozzle and should be periodically cleaned.
•
Nozzle maintenance - If the spray of the nozzle becomes blocked, slide the nozzle cover off and remove the nozzle. Wash the
nozzle in clean water, ensuring that the nozzle is clear before refitting.
•
Wipedown the outside of the steam generator with the damp cloth, only after the unit has cooled down.
•
Regularly clean the nozzle with water and dry.
WARNING - Regular descaling must be carried out otherwise damage maybe caused to the machine. For instructions,
please refer to the pictorial at the back of this manual.
AFTER SALES SERVICE
Truvox machines are high quality machines that have been tested for safety by authorised technicians. It is always apparent that
after longer working periods, electrical and mechanical components will show signs of wear and tear or ageing. To maintain
operational safety and reliability the following service interval has been defined: Every year or after 250 hours. Under extreme or
specialised conditions and/or insufficient maintenance, shorter maintenance intervals are necessary.
Use only original Truvox spare parts. Use of other spare parts will invalidate all warranty and liability claims. Should you require
after sales service please contact the supplier from whom you purchased the machine, who will arrange service. Repairs and
servicing of Truvox products should only be performed by trained staff. Improper repairs can cause considerable danger to the
user.
GUARANTEE
Your product is guaranteed for one year from the date of original purchase, or hire purchase, against defects in materials or
workmanship during manufacture. Within the guarantee period we undertake at our discretion, to repair or replace free of charge
to the purchaser, any part found to be defective, subject to the following conditions:
5