Installing and removing wire racks
To remove wire racks, press the clips shown with arrows in the figure,
first remove the lower, and than the upper side from installation
location. To install wire racks; reverse the procedure for removing wire
rack.
Replacement Of The Oven Lamp
WARNING: Disconnect power supply and wait for the oven to cool
down to eliminate the risk of electrocution before replacing the oven
lamp. Hot surfaces may cause burns.
Remove the glass protector by rotating it. Using plastic gloves may
help you if you have difficulty in rotating it.
Then, remove the lamp by rotating it, and install the new lamp with the
same specifications. Replace the glass protector, plug the appliance
and complete the replacement procedure. You may now use your oven.
Type G9 Lamp
2.4. Troubleshooting
You may solve the problems you may encounter with your product by
checking the following points before calling the technical service.
Check Points
In case you experience a problem about the oven, first check the table
below and try out the suggestions.
Multifunction Built in Oven | Horno Multifunción | Forno Multifunções
AF BECKEN manual Forno multifuncoes BBIO5046 A5 (3).indd 35
AF BECKEN manual Forno multifuncoes BBIO5046 A5 (3).indd 35
Type E14 Lamp
220-240 V, AC
15-25 W
Fig. 5
220-240 V, AC
15 W
Fig. 6