E. Sleep mode
Sleep mode can be activated in cool mode.
In cooling mode
1 hour after turning on the sleep mode, the set temperature is automatically
increased by 1 ° C and after 1 hour automatically by 1 ° C. After 2 hours, the set
temperature is no longer increased.
12 hours after turning on sleep mode, the device turns off automatically.
TIMER SETTING (1 hour - 24 hours):
The timer can be operated in two ways:
Switch off:
Press the Timer button to turn on the timer function. Press ADD/MINUS repeatedly to
set the power off delay time.
Turn on:
Press the Timer button to turn on the timer function. Press ADD/MINUS repeatedly to
set the power on delay.
Cancel timer
Press ADD/MINUES repeatedly until the LED shows '00'.
Automatic:
At low room temperatures, frost may accumulate on the evaporator during
operation. The device automatically starts thawing and POWER LED flashes. The
sequence of defrost control is as follows:
C. When the device is operating in cooling and dry operation, the ambient
temperature sensor detects that the temperature of the evaporator coil is
below -1 °C. When the compressor is stationary for 10 minutes or the coil
temperature is up to 7°C, the device will start cool mode of operation again.
D. When the device is operating in drying mode, the device starts as soon as the
coil temperature sensor detects that the temperature of the evaporator is
below 40 ° C and the difference temperature between coil temperature and
room temperature is below 19 ° C after the compressor has been in operation
for 5 minutes and the mains indicator flashes.