6.3
V-TEC Tieback Fall Clearance Charts
1.8 m V-TEC Tieback PFL: 1.8 m / 6 ft Lifeline + 0.9 m / 3 ft Tieback (Total Length: 2.7 m / 9 ft)
V-TEC Tieback Single PFL
Product: V-TEC
Tieback PFL
Use: Non-leading edge
applications
Capacity: ≤ 310 lbs (140
kg)
NOTE: OSHA limits free
fall to 2 ft (0.6 m) or less.
Product: V-TEC
Tieback PFL
Use: Non-leading edge
applications
Capacity: ≤ 400 lbs
(180 kg)
NOTE: OSHA limits free
fall to 2 ft (0.6 m) or less.
NOTICE
If the V-TEC Tieback PFL is anchored around a structural member that has been suitably identified by a qualified person,
the fall clearance may be reduced by an amount equal to the circumference of the object, up to 3 ft (0.9 m).
7
Pre-Use Checks and Periodic Examinations
The safety of the user relies upon the continued efficiency and durability of the equipment, therefore pre-use checks shall
be completed before each use. See Table 1 Pre-Use Checks, for pre-use check information. Periodic examinations shall
be completed by a person, other than the user, competent in the examination of PFLs, in accordance with the
manufacturer's instructions. The interval will be dictated by the usage, local regulations, and environmental conditions, and
will be at least annually (see Table 2 Periodic Examination Interval). A record shall be kept of the results of the
examination.
US
7 Pre-Use Checks and Periodic Examinations
V-TEC Tieback Twin PFL
V-TEC® PFL
14