SUB-X™ LT or C-Level™ Sensor Sensor Positioning
Stow excess tube using a
cable tie.
Caution: Do not overtighten
and pinch vent tube.
Do not use the hose clamp
to attach the vent tube.
Doing so will cause sensor
to fail.
4 inch (10.2 cm)
minimum set level
0 inch (0 cm) liquid
level measured from
approximately this point
1 inch (2.5 cm)
minimum from bottom
of tank or from sludge
Timed Dose
high water
alarm
timer
override
timer
enable
redundant
o
0
Float Switch Positioning
cable
tie
hose
clamp
Demand Dose
high water
alarm oat
(recommended)
redundant o
oat
(recommended)
CAUTION!
If the SUB-X ™ LT sensor,
C-Level ™ sensor or oat
switches are not mounted
and connected correctly,
the pumps and alarm will
not operate properly.
3.5"
(9 cm)
ag (duplex
l
only)
high water
alarm
lead
stop
0
high water
alarm oat
(recommended)
redundant
o
oat
(recommended)
EN3