 Completely unscrew the two yellow bushings connected to the peristaltic 
pump hose (B. in figure). 
 Disconnect the two Teflon hoses from the couplers. 
 Pull outward the hose support (C.  in figure) to extract it from the pump 
body. 
 Remove  hose  and  support  by  favouring  the  hose  exit  (A.  in  figure) 
through the manual rotation of the cam and reject them. 
 Unloosen  the  coupler  joining  the  non‐return  valve  (D.  in  figure)  to  the 
injector plexiglas bloc. 
 Remove the non‐return valve and reject it. 
 Fit the new non‐return valve in place of the old one and deeply clamp the 
coupler  on  the  injector  Plexiglas  bloc.  Adjust  the  vale  hoses  length  by  
using a hose cutter. 
 Fit  the  new  hose  of  the  pump  by  fixing  firstly  the  support    (C.  in  figure) 
and  then  by  fitting  the  hose  under  the  cam;  favours  this  operation  by 
manually rotating the cam. 
 Reconnect the two Teflon hoses to the relevant couplers. 
 Fully  clamp  the  yellow  bushings    (B.  in  figure)  and  be  sure  the  Teflon 
hoses are correctly fitted, by pulling them. 
 Switch  on  Biox  and  press  button  "Manual  dosing"  (see  Fig.  14).  While 
holding  down  the  button  check  for  the  correct  fitting  of  the  hose  under 
the cam. 
 Reposition  the  bottle  containing  the  chlorine  dioxide  solution  into  its 
housing and clamp well the red cap. 
 Switch the Biox off and on again. 
 Hold down the button "Manual Dosing" until the dosing pump stops and 
the yellow LED "Dosing" turns off (approx 5 seconds). 
 Repeat  several  times  the  operations  described  in  the  two  points  above 
while  being  sure  the  chlorine  dioxide  solution  is  sucked  by  the  pump, 
reaches and passes through the non‐return valve and enters the Plexiglas 
bloc of the injector. Check for the absence of leaks. 
 Remount the external cover of the Biox hydraulic component . 
 Re‐open the cock on the storage tank . 
 Switch on the machine, start it by picking water from a utility and check 
for  the  correct  operation  of  Biox,  by  checking  the  lights  on  the  control 
panel. 
 
N.B.:  The  peristaltic  pump  hose  and  the  non‐return  valve  have  to  be 
disposed of as special waste.  
 