Idiomas disponibles

Problem
Possible
Cause
Probable
Correction
Water is leaking
from the unit.
Cubes are partially
formed or are
white at the
bottom.
The ice cubes are
incomplete
when
being dumped.
Noise during
operation
The ice maker
stops suddenly
while making ice.
The body of the
ice maker is
electrified.
Scale occurs
frequently
inside
the machine.
A few water drops fall to
the floor when you open the
door to take out ice from
ice storage bin.
Water supply connection
leaking.
Nut of water drain hole
leaking.
Drain hose connection
leaking.
Not enough water in the
water sump.
The sprinkler is blocked.
The feet are not leveled and
locked.
Certain sounds are normal.
The electricity
is off.
The room temperature
is
out of the stated range.
The ventilation louvers are
covered.
The grounding
line isn't in
the socket.
The hardness of the water is
too high.
Normal condensation
on the door or
some water together
with ice. Take
care when you take out ice.
Tighten
fitting.
See "Connecting
the
Water
Line".
Tighten
the nut.
Tighten
fitting.
See "Connecting
the
Drain':
Check if the water supply pressure
is
below 20 psig.
Check water supply; filter may be
restricted.
Check for a water leak at the water sump.
Check if water inlet valve is restricted.
Clean it; see '_nterior
Cleaning".
Level
and lock the feet.
See 'Leveling
the Ice Maker".
See "Normal
Sounds".
Reconnect
the power supply line.
Cut off the electricity;
let the ice maker
stop working till the temperature
returns within the stated range.
Remove the obstruction.
Use a socket meeting the required
electrical standard.
Use a water-softening
device installed
in front of the water inlet valve.