Refilling The Tank - Nikken PIMAG WATERFALL Manual De Uso

Ocultar thumbs Ver también para PIMAG WATERFALL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Do not overfill the unit. If the lower (supply) tank is 1/2 full, do not fill the upper (fill) water tank more
than halfway. Overfilling the tank may cause the unit to overflow.
IMPORTANT: The white polymer connector for the wire to the tap assembly is designed to fit in one
direction only. If this is disconnected and resistance is felt when reattaching, do not attempt to force it
into place. Reverse its position to reconnect.
Keep the PiMag
Waterfall
Component replacement
Hand wash the water tanks periodically (approximately once a month) to keep them clean and free of
deposits. You may use a mild detergent or soap. When cleaning the unit, do not use a scrubber or
paper towels, which may result in scratches on the surface. Use a soft cloth to dry.
The prefilter may be rinsed or flushed if it becomes discolored or water flow is reduced. Use cold water only.
Do not boil the filter cartridge. Clean only by rinsing in cold water.
The replacement filter must be prepared by soaking (preferably for 8 hours) before installation.
Follow steps 3 through 5 as described in the Assembly Instructions in this manual.
After changing the filter (and prefilter pads), reassemble the Waterfall. Fill the unit with cold water. Then
press and hold the LED indicator button for 8 to 10 seconds, to reset the indicator for a new cycle. The
Replacement parts
®
display will flash in all colors and then reset to show a green light.
• After the water has filled the supply (lower) tank, pull outward on the water tap lever to lift until it
locks in the open position, to drain the Waterfall. Fill and drain the unit while the tap is open, for
two full cycles.

REFILLING THE TANK

Filter cartridge life will vary, depending on amount of use and water quality.
Recommended replacement for mineral stones at least once per year.
The following replacement parts may be ordered from Nikken Inc.
Filter cartridge #13845
Mineral stones #13846
MAINTENANCE
Problem: Unit is leaking.
Cause: Loose seal at the water tap.
Solution: Make sure that the magnetic tube (inside the water supply tank) is firmly tightened.
Do not overtighten.
Problem: Water has a disagreeable taste or odor.
Cause: Poor water quality or filters need replacing.
Solutions: (1) Check quality of water used in system. (2) Clean or replace prefilter. (3) Replace filter
cartridge.
Problem: Reduced water flow through unit.
Cause: Air retained in prefilters.
Solution: Remove all five (5) prefilter elements, compress them by squeezing each one under water to
expel air bubbles, replace.
TROUBLESHOOTING
Gravity Water System away from direct sunlight.
®
7

Publicidad

Tabla de contenido
loading

Tabla de contenido