A200 Drinking Water System
H. Disconnect the tubing from the storage tank valve and put the tubing end
into a bucket or pan. Open the cold water supply valve and allow the product
water to discharge from the tubing into the bucket or pan for 15 to 20
minutes. This should adequately flush the sanitization solution through the
membrane. Close the cold water supply valve after this time. Reconnect the
tubing to the storage tank valve. If the tubing end is scarred or scratched, cut
away the damaged end before connecting it to the tank.
IMPORTANT: You must properly rinse the membrane sanitizing solution
NOTE: The serial number is located on the data plate that is attached to the
inside of the bracket cover. If your system is installed on a chlorinated
water supply, use a high capacity carbon/sediment prefilter
(Part No. 9461A) to remove the chlorine before the membrane.
If your system is installed on a non-chlorinated water supply, use a
sediment prefilter cartridge (Part No. 9309A).
Using a carbon/sediment prefilter on an unchlorinated supply may
cause a bacteria/odor problem.
A200 reverse osmosis systems can only be used for arsenic reduction
on chlorinated water supplies containing detectable residual free
chlorine at the system inlet. This chlorine must be removed with a
high-capacity carbon/sediment prefilter (Part No. 9461A).
I.
Remove the sanitizer cartridge from the prefilter head on the left-hand
side of the system and install the new prefilter cartridge
J.
Open the tap. Open the cold water supply valve.
K. Open the valve on the tank. The tank should now be discharging water
through the open drinking water tap. This will flush away any carbon fines
from the new postfilter cartridge. When the flow slows to a drip, close
the tap. Allow the system to fill the storage tank for several hours. Discard
the water in the tank after this time. A four (4) tank flush is required per
installation instructions. Allow the system to fill the tank and begin enjoying
your clean, clear water.
from the membrane. DO NOT drink the water from the
system during this rinsing procedure.
9