Troubleshooting - Sunex Tools SX70C Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTINg

SPRAY PATTERN/
CONDITION
Spitting
Improper spray pattern.
Unable to get round spray.
Will not spray.
Fluid leak­age from
pack­ing nut.
Dripping from fluid tip.
Thin, sandy coarse finish.
Thick, dimpled finish
resembling orange peel.
SX70C: Parts Breakdown & Operating Manual
PROBLEM
One side of nozzle wing is
clogged.
A.) Loose air nozzle.
B.) Material around outside of
air nozzle has dried.
A.) Atomization air pressure is set
too high.
B.) Trying to spray a thin material
in too wide a pattern.
A.) Pack­ing around needle valve
is dried out.
B. Fluid nozzle loosely installed,
or dirt between nozzle
and body.
C.) Loose or defective swivel nut
on siphon cup.
A.) Gun improperly adjusted.
B.) Dirty air cap.
C.) Fluid tip obstructed.
D.) Sluggish needle.
Fan adjustment screw not
seating properly.
A.) No air pressure at gun.
B.) Fluid pressure too low with
internal mix cap and
pressure tank­.
C.) Fluid control screw not
open enough.
D.) Fluid too heavy for
suction feed.
A.) Pack­ing nut loose.
B.) Pack­ing worn or dry.
A.) Dry packing.
B.) Sluggish needle.
C.) Tight packing nut.
D.) Worn fluid nozzle or needle.
A.) Gun held too far from surface.
B.) Atomization pressure set
too high.
Gun held too close to surface.
SOLUTION
Soak­ nozzle in solvent to loosen clog, then blow air through
until clean. To clean orifices use a broom straw or toothpick­.
Never try and detach dried material with sharp tool.
A.) Tighten air nozzle.
B.) Tak­e off air nozzle and wipe off fluid tip,
using rag moistened with thinner.
A.) Reduce air pressure.
B.) Increase material control by turning fluid
control screw to left, while reducing spray
width by turning spray width adjustment
screw to right.
A.) Back­ up k­nurled nut, put a few drops of
machine oil on pack­ing, re-tighten nut.
B.) Tak­e off fluid nozzle, clean rear of nozzle and
seat in gun body. Replace nozzle and bring in
tight to body.
C.) Tighten or change out swivel nut.
A.) Readjust gun. Follow instructions carefully.
B.) Clean air cap.
C.) Clean.
D.) Lubricate.
Clean or replace.
A.) Check­ air supply and air lines.
B.) Increase fluid pressure at tank­.
C.) Open fluid control screw.
D.) Thin material or change to pressure feed.
A.) Tighten, but not so tight as to grip needle.
B.) Replace pack­ing or lubricate.
A.) Lubricate.
B.) Lubricate.
C.) Adjust.
D.) For pressure feed, replace with new fluid nozzle
and needle.
A.) Move gun closer to surface.
B.) Adjust atomization pressure.
Move gun further from surface.