Watts FloodSafe WDS-SI Serie Manual Del Usuario página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Remove Jumper to T T Terminals
T1
Oil Burner
Primary
T2
Relay
Figure 7
3. Using two conductor thermostat cable (supplied by the installer) install the spade terminals to one side of the cable and fasten termi-
nals to the other side of the cable. Connect the cable from the Power Cutout Module Terminal C (common) and NO (normally open) to
the TT terminals on the Oil burner Primary Relay as indicated in Figures 8 and 9. Install the connecting cable Figure 15 to the Power
Cutout Module terminals R1 and R2. Route the connecting cable to the Control Unit and insert the interlocking connector end to the
circuit board.
4. Proceed to Step 5 to continue installation
Figure 10
Spark Ignition Water Heater Installation (for Oil Fired Water Heater Installation, see page 2)
NOTE: Be certain to disconnect the circuit breaker/fuse that supplies power to the water heater. A warning label should be applied to
the panel with a warning against restoring power while work is in process.
1. Mount the Power Cutout Module as close to the electronic control module as possible.
2. Remove the wire from the Electronic Control "SPARK" terminal that goes to the Pilot Electrode Assembly from Electronic Control as
shown in Figure 11.
3. Using two-conductor thermostat cable, install the spade terminals to one side of the cable and then fasten terminals to the other
side of the cable. Connect the cable from the Power Cutout Module Figure 14 Terminal C (common) to the SPARK terminal of the
Electronic Control and NO (normally open) to the Pilot Electrode Assembly as indicated in Diagram 2, Figures 12 and 13. Note: We
have made every effort to provide all of the hardware required for a complete installation. However, the terminal connections used to
connect the Pilot Electrode Assembly to the Electronic Control vary by manufacturer, although we have included several connectors
used by leading manufacturers with your WDS, your specific mating connectors may not be included. If the required connector is
not included, it may be purchased locally at any electronic supply store. Install the Connecting Cable Figure 15 to the Power Cutout
Module terminals and R1 and R2, route the Connecting Cable to the Control Unit and insert the interlocking connector end to the
circuit board.
4. Proceed to Step 5 to continue installation.
POWER CUTOUT MODULE
R1
To Control Unit
R2
C
To Electronic Control
To Pilot Electrode
Assembly
Figure 13
OIL BURNER
PRIMARY RELAY
T1
T2
Figure 8
Electronic Control
Before
Figure 11
NO
NC
Figure 14
POWER
CUTOUT
MODULE
NC
C
NO
TO
R1
CONTROL
UNIT
R2
Pilot Electrode
Assembly
SPARK
3
POWER CUTOUT MODULE
R1
To Control Unit
R2
To T T terminals on Oil Burner Relay
Figure 9
Electronic Control
SPARK
To Power
After
Cutout Module
Terminal
C
Figure 12
Figure 15
NO
NC
C
Pilot Electrode
Assembly
NO