Electricity Supply - Electrolux ControlBox 24/7 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22

ELECTRICITY SUPPLY

The unit is powered by the voltage adapter supplied (230V AC / 12V DC 1A)
Rechargeable backup battery:
If the unit is deactivated by a power outage, the integrated battery will power it for up to 12 hours. The battery will
be recharged as long as the external power supply is connected. A full battery charge takes approx. 48 hours.
If the external power supply is disconnected for more than 15 seconds, the power indicator light will go out, and
15 minutes later, a text message stating "AC Power - FAIL, (15 minutes ago)" will be sent.
When the external power supply is reconnected, the power indicator light will come on, and 15 minutes later, a
text message stating "AC Power - RESTORED, (15 minutes ago)" will be sent.
If the battery is low, the battery indicator light will start to flash when 20% of battery capacity remains. 3 minutes
after the light starts to flash, the following text message will be sent: "Battery - LOW".
When the external power supply has been restored for more than 15 seconds, the battery indicator light will
come on again. The battery will be fully charged again after charging for approx. 48 hours.