5.8 Cleaning the exchangers with turbulator-shaker device
The fume ducts inside the heating chamber must be cleaned at least once a day by operating the two knobs
repeatedly with an upward and downward movement after opening the sliding cover.
Carry out this operation with the stove off and cold.
RH - LH control knobs of the turbulator-
shaker device in heating stove operation
low position.
6 MAINTENANCE
6.1 Introduction
Operations on the internal parts of the stove must be carried out by qualified personnel.
Contact the nearest authorised service centre.
Make sure the stove is unplugged and cold before carrying out any work on it.
6.2 Removing the cladding
Key:
1 - Top cover ceramic
2 - Tile upper right side
3 - Tile lower lateral right-left
4 - Tile upper left side
5 - Top front panel ceramic
6 - Bottom front panel steel
7 - Extensions with knob for turbulators
50
TERMO ORIONE PLUS