TDK-Lambda CUS100ME Manual De Instrucciones página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
CUS100ME Handbook
Mounting
Customer fixings, at locations A, B, C and D, must not bridge Creepage and Clearance distance spacing.
Ensure the following creepages and clearances are maintained for customer fixing points A, B, C and D.
Based on IEC/EN/UL60950-1
At 3000m operation, 2.3mm Clearance, 2.5mm creepage
At 4000m operation, 2.6mm Clearance, 2.6mm creepage
At 5000m operation, 3.0mm Clearance, 3.0mm creepage
IEC/EN/UL60601-1
At 3000m operation, 2.5mm Clearance, 4mm creepage
At 4000m operation, 2.9mm Clearance, 4mm creepage
At 5000m operation, 3.3mm Clearance, 4mm creepage
IEC/EN/UL62368-1
At 3000m operation, 1.8mm Clearance, 2.4mm creepage
At 4000m operation, 2.0mm Clearance, 2.4mm creepage
At 5000m operation, 2.3mm Clearance, 2.4mm creepage
All four mounting points (A, B, C, D) should be used to support the unit.
TDK-Lambda UK Ltd
Kingsley Avenue, Ilfracombe
Devon, EX34 8ES
Telephone - Sales and Service +44 (0)1271 856666
Head Office and Works +44 (0)1271 856600
Facsimile +44 (0)1271 864894
WEBSITE: www.uk.tdk-lambda.com
Page 24 of 24
260423-3 Mar 2019

Publicidad

Tabla de contenido
loading

Tabla de contenido