UHI/UHO Series
CAUTION!
Always securely tighten all fittings to ensure a liquid-tight seal.
Failure to do so could allow water to enter the housing and
damage the camera and lens. If a sealant is used, be sure it is a
neutral cure type. Sealants that release acetic acid may harm
camera electronics. Use of drip loops is recommended on the
wiring outside of the rear end cap.
5.7.2
Conduit
These housings allow direct connection of conduit.
1.
2.
5.7.3
Feed-through Wiring
Use feed-through mounts to feed cabling through the foot of
the housing.
1.
2.
Bosch Security Systems, Inc.
Remove the rear hole plugs and attach the conduit and
conduit fittings directly to the housing rear cap. The holes
accept either 3/8-inch NPT or 1/2-inch NPT conduit
fittings.
Any unused holes must be covered using the plugs
provided with the housing.
Prior to mounting the camera, remove the two dome plugs
located inside the housing See Figure 5.6.
Figure 5.6 Location of feed through wiring holes.
Screw the two 3/8-inch NPT fittings into the foot of the
housing.
Installation Manual
Installation | en
F.01U.167.418 | 3.0 | 2010.04
63