USER INTERFACE
Indicator LEDs:
Status LEDs (RDNet network):
Controls
INPUTS AND OUTPUTS
Power supply inputs and links:
Audio inputs:
Audio outputs:
RDNet inputs/outputs:
USB (firmware update):
POWER SUPPLY SPECIFICATIONS (CONSUMPTION)
Consumption at 1/8 of the power
under
normal operating conditions (*):
Consumption at 1/3 of the power
under
maximum operating conditions (**):
Consumption with speaker on and
no signal (idle):
Inrush current:
Maximum number of modules per
power supply line (**)
[mains input + mains link]:
* NOTE FOR THE INSTALLER: Values refer to 1/8 of the power under normal operating conditions (musical program with rare or no clipping).
For any configuration type, we recommend considering them to be the minimum values for dimensioning.
** NOTE FOR THE INSTALLER: Values refer to 1/3 of the power under heavy operating conditions (musical program with frequent clipping
and limiting). We recommend dimensioning according to these values for installations and professional tours.
VIO-S118R
50
Limiter, Signal, Mute/prot, Ready
Link, Active, Remote Preset Active
Polarity (0°/180°), Delay (0–9.9 ms), Cardioid Function, Xover
Frequency (
70-75-80-85-90-95-95-100-105-Fullrange
PowerCON® In/Link
1x balanced XLR IN (isolation: Floating ADC )
1x balanced XLR link OUT, HPF Xover audio
Data In / Data Out (etherCON® connectors)
1.4 A (220 - 240V~) - 2.7 A (100 - 120V~)
3.4 A (220 - 240 V~) - 6.8 A (100 - 120 V~)
1+3 (220-240V~) / 1+1 (100-120V~)
), Sub Attenuation
1x type B USB
33 W
3 A
Cod. 420120271 REV. 1.0
English