Note: the TRIGGER control signal is not a power-free contact closure; rather, it operates
thanks to a circuit based on MOSFET devices. For more information, consult the technical
features of the equipment.
3.
Adjust the microphone level of the receiver equipment
The console (2) microphone is a non-extractable electret cardioid type mounted on a
flexo. It is supplied with an "anti-pop" foam windshield.
4. OPERATION
Once the MPAGE1 unit is connected to the receiver, messages are sent by pressing the
PAGE (1) key and keeping it pressed while the voice message plays.
If the receiver has a "talkover" function that works by automatically detecting the signal
delivered by the microphone or by closing the external contact using the TRIGGER (4) connector, the
sound in the areas where the message is being received will be attenuated or muted
x
while the message is being delivered if there is automatic level detection (PAGE (1) key
pressed + message playing)
or
x
as long as the PAGE (1) key is pressed if activated by closing the contact
6