Motor appears to
stall during juicing
All control panel
lights flash and
Overload Protection
displayed on
LCD screen
•
Wet pulp can build up under the juicer cover and stall the appliance if the
appliance is used excessively without cleaning. If this occurs, disassemble
and follow the cleaning instructions to clean the filter bowl surround, the
stainless-steel filter basket and the juicer cover. The appliance can also
stall if excessive force is used to push produce down the feed chute.
If this occurs, ensure that a gentler pressure is used to push produce
down the chute.
•
Turn on the appliance before putting ingredients in the chute. Pressing
ingredients down before the motor reaches full speed can cause it to
stall or overload. Use gentle to moderate pressure on the pusher.
Lower pressure produces a better juice yield.
•
Hard fruit and vegetables will put excess strain onto the motor if a low
speed is selected. Refer to the reference guide to determine the correct
speed for the fruit and vegetables selected for juicing.
•
This indicates motor overload protection is activated due to motor
overheating or stalling.
•
To reset the protector, unplug from the power supply, then plug back in
and turn on.
•
If overload protection is still displayed, unplug the appliance and leave
to cool for at least 30 minutes, then try again. The appliance must be
unplugged while cooling in order to reset properly.
•
If the issue persists after allowing to cool, this indicates an internal problem.
Contact Sage Customer Service or go to www.sageappliances.com.
•
Note that triggering the overload protection indicates abnormal use of
the appliance, such as too much load in the blender jug, excessive push
force when juicing or extended continuous use. Please take note of the
conditions and refer to all of the information in these instructions to avoid
this occurrence and extend the life of the appliance.