9. STORAGE INSTRUCTIONS

1. Charge battery to full capacity before storage.
2. Store this unit at temperatures between - 4°F- + 140°F ( - 20°C- + 60°C).
3. Never completely discharge the battery.
4. Charge after each use.
5. Charge at least once every month, if not in frequent use, to prevent
over-discharge.

10. TROUBLESHOOTING

PROBLEM
The jump starter turns on, but
won't jump start my vehicle.
All four LEDs flash.
The last LED flashes, then
turns off.
The green LED on the smart
cable does not light when its
button is pressed.
Smart Cable LED Behavior
Green LED lit solid
Green LED flashes three times Reverse charging protection
Red LED flashes once
Red LED flashes twice
Red LED flashes four times
Red LED flashes five times
Red LED lit solid
REASON/SOLUTION
Make sure you have pressed the smart
cable's
button.
Verify the charge level of the jump starter is
at least 50%.
Do not attempt to jump start your vehicle
more than three consecutive times. If
the vehicle still does not start, consult a
qualified service technician.
Low or high temperature. LEDs will stop
flashing when the condition is corrected.
Over-discharge. Recharge the internal
battery.
Check connections.
If an LED is flashing, refer to the table
below. When the condition is corrected,
the smart cable will automatically reset.
Ready to jump start
Reverse polarity protection
Short circuit protection
Low voltage protection
High temperature protection
OK to press
• 10 •
button to jump start