STANDARD
Minimum Floor Thickness
Anchor
Minimum Concrete Strength
Minimum Anchor Embedment
Minimum Distance to Concrete
Edge, Crack, Expansion Joint,
Abandanoned Anchor Hole
*The supplied concrete fasteners meet the criteria of the American National Standard
"Automotive Lifts - Safety Requirements for Construction, Testing, and Validation" ANSI/ALI ALCTV-2011, and
the lift owner is responsible for all charges related to any additional anchoring requirements as specified by
15. Grouting
If lift must be shimmed, Fig. 10, the base must be
grouted to provide continuous support. Grout must
conform to ASTM C1107 and min. 5,000 psi (34 mpa).
Drill holes using 1/2" carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
CONCRETE AND ANCHORING REQUIREMENTS
ANSI/ALI ALCTV
IBC 2006, 2009, 2012
4 INCHES (102mm)
Hilti Kwik Bolt III
1/2" x 4-1/2"
Anchors supplied with
the lift.*
3000 PSI (20684 kPa)
2-1/4 INCHES (57mm)
3 INCHES (76mm)
Contact customer service for further information at: 800.445.5438
Run nut down just below impact
section of bolt. Drive anchor
into hole until nut and washer
contact base.
Varies by location consult
with your structural engineer and manufacturer's
local codes.
WARNING
If the floor is not level the platforms will
not be level which could result in unsatisfactory lift
performance, property damage, or personal injury.
21
Tighten nut with Torque
wrench to 40 ft.-lbs
(54 Nm).
SEISMIC
representative.
.