Check the turning direction: counter clockwise viewed from the front of the pump (fig.3).
3.4 Priming
Pump loaded: open the valves (a, b) so that the load liquid floods the body of the pump and it is primed
(fig.1).
Pump in sucton: fill the suction tube with liquid and the body of the pump through the discharge intake
or through the top filling cap (fig.2). When starting the pump it will take a while to fully prime the tubes,
which will vary depending on the diameter and length, and may be between 1-5 minutes.
Once primed check that there are no losses of liquid through the joints on the tubes, valves, etc.
3.5 Start-up
Check that the motor's voltage is the same as that of the network.
Check that the motor is connected correctly according to instructions.
Check the turning direction (fig.3)
With the discharge valve open start the motor. When the pump is primed close the valve until the desired
flow or pressure is obtained. Next check that the electrical consumption in amperes is correct, within the
limits indicated on the specification plate.
If the pump does not operate as required once started, check the priming, turning direction and
connections of the motor.
4
Maintenance
Defective or incomplete maintenance may lead to incorrect operation of the machine (with increased
incidence and therefore costs from insufficient quality).
Good maintenance enables incidents to be reduced in the process and at the same time
guarantees compliance of the product's requirements and specifications.
National regulations must be observed.
It is the user's responsibility to establish an inspection plan defining the necessary
intervals and maintenance of these appliances with the aim of guaranteeing their correct
use.
Inspections must be carried out by personnel qualified for the type of appliance and/or installation.
It is recommended to carry out the following actions/checks with the aim of ensuring correct operation
of the Bominox pumps.

4.1 Replacing spare parts

In addition to these, also see the attached instructions from the original manufacturer.
EN 10
Does not
work dry.
Fill the
body with
liquid.

Hide quick links: