Possibilities Of Failure; Technical Details - Airpress HLO 215/25 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.0 POSSIBILIBIES OF FAILURE
1 Compressor does not run at starting pressure:
* blown fuse
* tank at pressure
* motor broken
* defective pressure switch
2 Repeating thermal failure:
* blown fuse
* loose wire
* pressure switch does not release
air circuit
* too low voltage
* overloading
3 Compressor keeps blowing off air:
* defective non-return valve
4 Too little air production:
* dirty air filter
* defective valves
5 Leaking safety valve:
* pressure too high
* defective safety valve

8.0 TECHNICAL DETAILS

Motor power
Volt
Air tank capacity
Operating pressure
Maximum pressure
Sound pressure
Service
Air intake capacity
Weight
Dimensions (lxwxh)
Model changes reserved.
- renew the fuse
- discharge
- repair/renew
- repair/renew
- renew fuse
- repair
- repair/renew valve
- remove extension cable or use heavier
- reduce loading
- repair/renew
- clean/renew filter
- renew
- set pressure switch
- renew
1,1 kW/1,5 HP
230 V/50 Hz
25 litres
6 bar
8 bar
78 dB(A)
30% per hour
215 l/min.
23 kg
580 x 325 x 560 mm