APPROPRIATE USE

The GAS ALARM GX-C3pro with external sensor is a gas warning device for carbon mo-
noxyde and can already deliver a warning at a gas concentration that lies well below life-
threatening values. This monitoring system is, therefore, in line with its purpose, set to a very
high sensitivity (see table TECHNICAL DATA). The alarm is signalled acoustically/optically
and the connected gas appliance is turned off at the same time. The unit is suitable for normal
household use and may not be used in areas at risk of explosion.
Another use of the device as described above is not authorized.

TECHNICAL SPECIFICATIONS

Operating voltage:
Power consumption:
Switching capacity:
Protection type:
Acoustic pressure sounder:
Type sensor:
Operating temperature:
Storage temperaturer:
Humidity (ambient):
Service life:
Cable length:
Cable Ø:
Dimensions (HxWxD):
Dimensions sensor (HxWxD):
data diagramm
Sensor
gas type
CO
8
230 (+/-10%) V AC / 50-60 Hz
approx. 2 VA
1150 W / 5 A
IP 20
85 dB @ 1 m
electrochemically
-10 °C / +50 °C
-20 °C / +70 °C
5–90 % RH (non-condensing)
approx. 5 years
2.5 m
3.5 mm
121x57x38 mm
88x58x38 mm
as described in DIN EN 50291
minimum
concentration
< 30 ppm
30 - 50 ppm
50 - 100 ppm
100 - 300 ppm
> 300 ppm
Alarm delay time
no Alarm
2 hours
1 hour
10 minutes
< 3 minutes