Descargar Imprimir esta página

König SAS-ALARM100 Manual De Uso página 8

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Note:
1) The alarm unit will give a conformation tone when armed or disarmed. The
tone for CHIME is different as for ALARM.
2) If a sensor does not need to be switched on, it's possible to switch off every
sensor individually with the on/off switch. In this case the sensor is no part
of the alarm system anymore when armed (except PIR sensor).
3) A sensor switched to RF+ALARM will always give an alarm sound on the
sensor itself, unless the alarm unit is armed or disarmed.
4) When a sensor is triggered and the siren of the alarm unit sounds, it needs
to be switched off with on/off switch of the alarm unit. After that the alarm
unit can be switched on again. When the alarm keeps on going after arming
the system, check if every sensor is installed properly.
Installation SAS-ALARM120
1. Insert, according the diagram inside the battery compartment, (backside)
the batteries for the alarm unit (3x AA).
2. Install the door/window sensor with the adhesive tape to doors and
windows. Note: maximum 1 cm distance between magnetic contact and
sensor (see figure 2). Switch on the sensor to RF or RF+ALARM. If switched
to RF+ALARM, the sensor will send, when triggered, a signal to the alarm
unit and the siren of the sensor itself will also sound. In this case the siren of
the sensor and the alarm unit will both sound.
3. Insert, according the diagram inside the battery compartment, (backside)
the batteries for PIR sensor (3x AAA). The PIR sensor needs to warm up for
30~40 seconds for first use. In this period it cannot detect motion. Install
the PIR sensor at a height of 1~1.5 m for best performance. Do not install
the PIR sensor into direct sunlight, facing towards windows, objects that
move easily and heat or cold source.
4. Remove the transparent front cover of the alarm unit to write down the
position of the sensors corresponding with the numbered LED. (e.g. sensor
1=front door, 2=kitchen window, etc.).
5. Install the alarm unit to a location. The distance between the alarm unit and
the most far away sensor may not exceed 60 m (open area)*.
6. Switch on the alarm unit to ALARM or CHIME function. If switched to
CHIME, the alarm unit will sound like a door bell when a door or window is
opened. Switched to ALARM generates a 100 dB loud siren. When the alarm
unit is switched on, the alarm is not armed (active) yet. Push the ON button
8
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

Sas-alarm110Sas-alarm120Sec-alarm100Sec-alarm110Sec-alarm120