Installation Instructions
7) Connect the connector (1) from the fan mounting bracket to the input connector (1) from the receiver.
8) Connect the output connector (2) from the receiver to the connector (2) from the fan body.
9) Push the connected wires up into the canopy
10) Lay the receiver in the CANOPY. (See Fig. 4).
11) Reinstall the canopy on the mounting bracket.
12) Restore electrical power to the circuit.
Fig. 3 –a
CONNECTION METHOD VIA HARDWIRING – For use with Non LUCCI brand Ceiling Fans.
Connecting the remote receiver to the fan without the LUCCI loom connectors (or see Fig. 3-b).
1) Cut and remove the connectors from the receiver.
2) Throw away the earthing wire after cutting the connectors.
3) Strip the insulation to bare wire by 8mm length for each wire to prepare the wiring connections.
4) Switch OFF electrical power to the working circuit.
5) Remove the ceiling fan canopy cover from the mounting bracket and remove any existing wiring.
6) Connect the supply earth (GREEN/YELLOW) wire to "
" terminal of the terminal block on the mounting
bracket.