GRTx - LED Roadway Luminaire
General instructions
1)
The installation must be carried out by a qualified electrician who takes into account the instructions of
the document and the current regulations of the country's electrical systems.
The lighting and / or electrical source should only
be replaced by the manufacturer or its service
agent or, if applicable, by qualified personnel
Risk of Electric Shock
-Disconnect power before installation, inspection and
uninstallation.
-Connect the grounding / junction boxes correctly.
2) Technical Data
Power
380x180x230mm (GRT1)
Dimension
570x200x218mm (GRT2)
3) Installation
1. Connect the cables to the AC power, color
chart in the table below.
4) Wiring
NOTICE: This luminaire is designed for exterior lighting at temperature up to 50 ° C, consult the manufacturer for installation at higher temperatures. Refer to
the technical data sheet to check the electrical properties and ensure a safe installation. We recommend the use of a line with protection against both
permanent and transient overvoltage. The safety of the product can only be guaranteed if these instructions have been followed. Keep the instructions in a
safe place for future reference. Depending on the circumstances, the instructions contained in this document must be provided, along with any other
information that may be necessary, to any company or person involved in the installation of EG products.
ATTENTION: Risk of burns: do not touch the luminaire when it is switched on. Risk of burns: allow the light source to cool before handling the luminaire. If it is
not mounted properly, the luminaire will fall. Always follow the assembly instructions. Immediately replace the light module in case of damage or breakage of
the glass (the luminaire should never be used without the glass).
MAINTENANCE: Make sure the power supply is disconnected before performing any maintenance work. Periodic cleaning of the exterior of the glass will
ensure operation with maximum optical efficiency. The glass should be cleaned with non-abrasive soap, cleaner or detergent solution, rinse with cold water
and dry with a cloth. Data subject to change without notice.
ADDITIONAL INFORMATION: To ensure that the product warranty is valid, it is important that the installation instructions are followed and that the
conditions of storage and operation are complied with. Refer to the technical data sheet to check the electrical properties and ensure a safe installation.
30 - 70W(GRT1)
Weight
100 - 150W (GRT2)
EPA
2. Loosen the two M10x30 screws on
the clamp.
Power Cables
G – Ground
Green-Yellow
Luminaire
The luminaire should be placed in such a way
that it does not look directly at you for a
prolonged period of time.
Fire Risk
- Observe all local electrical codes.
-Use only IEC cables, approved for input / output connections.
4.1kg (GRT1)
5.2kg(GRT2)
0.063m2(GRT1)
0.244m2 (GRT2)
N –Neutral
Blue
Green
White
120-277Vac,50-60Hz
Input Voltage
FP > 0,90
IP66, IK08
Ratings
Max 50C (30-120W)
Op. Temp
Max 35C (>120W)
3.
Tighten the M10 screws
to secure the luminaire.
L - Line
Brown
Black