PA634-04-01C
Note: CE MARKING
CE Marking, when applied to a product covered by this handbook indicates compliance with the following:
Low Voltage Directive in that it is complies with EN60950-1 and EN62368-1.
EMC Directive
Restriction of the use of certain Hazardous Substances Directive
2. Terminal Explanation
2-1. DRB120
+V: +Output terminal
- V: - Output terminal
V.ADJ: Output voltage adjust trimmer
The output voltage rises when trimmer is turned clockwise
L: AC Input terminal
Live line (fuse in line)
N: AC Input terminal
Neutral line
: Protective Earth
Connect to safety ground of apparatus or equipment.
DC OK : Green LED lights when Output
voltage is turn on and within specification
- DC : Optocoupler
+ OK : Optocoupler
WIRING
CONNECTOR
Recommended Wire
INPUT
10~24 AWG
(L, N,
))
OUTPUT
10~24 AWG
(+V, -V)
OUTPUT
10~24 AWG
(DC OK)
Note: According to EN/UL60950-1 multi-
strand flexible cables connected to the input
require ferrule.
TDK-Lambda
DRB120 Series
INSTRUCTION MANUAL
Rated Torque
10.3 kgf.cm
(9 lbf.in)
10.3 kgf.cm
(9 lbf.in)
10.3 kgf.cm
(9 lbf.in)