Abus GRWM30500 Manual De Instrucciones página 32

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 156
Smoke alarm devices are to be used as the bare minimum equipment
bedrooms, children's rooms and hallways which act as escape routes, and are
to be installed in each case in the middle of the room, on the ceiling only (do not
install on wall) (Fig. 2).
Select the highest installation location with a minimum distance of 50 cm to
surrounding walls, furniture and lamps. Configuration
devices are located in all other rooms as well as staircases. In washrooms
(bathrooms, lavatories etc.), a smoke alarm device is generally not necessary
because the risk of fire is low.
Please observe the graphics in this guide.
Where smoke alarm devices should not be installed
Selecting location
Outside (use only in closed rooms)
In rooms in which the alarm could be triggered by
disturbance variables (steam, condensation, 'normal'
smoke, vapour, dust, dirt or grease)
Next to an air duct or similar ventilation opening (draughts)
In areas in which the temperature can fall below 0 °C and
rise over 40 °C
on unstable surfaces with designs that render them
unsuitable for installation with screw anchors.
RM
32
RM
is optimal when
in all

Publicidad

Tabla de contenido
loading

Tabla de contenido