6 Maintenance
The product requires no maintenance.
7 Taking out of operation
When installed and used for its intended purpose, the
product will perform continuously without issues.
8 Disposal
After termination of use, the purchaser or the operator
must properly dispose of the product including the
accessories.
This product was manufactured according to the current
environmental protection standards. The materials can be
separated and recycled.
f Observe the national regulations for the disposal of
recyclable materials.
f Do not dispose of the product with domestic waste.
f Take the product to a local collection point or recycling
centre.
f If necessary, contact your local environmental office.
9 Technical data
Characteristics
Safety class
Insulating properties
Ageing resistance
UV resistance
Weather resistance
Shelf life
Operating temperature
Scope of application
Reliseal V 56
Length
Width
Height
Cable diameter
Conductor cross-section
Reliseal V 510
Length
Width
Height
Cable diameter
Conductor cross-section
Reliseal V 525
Length
Width
Height
Cable diameter
Conductor cross-section
All dimensions in mm. We reserve the right to make technical changes without notice.
Minimum order quantities (MOQ) can deviate from the package contents.
Installation instructions • Reliseal • 07-2016
Maintenance
IP 68
> 1 kV
Yes
Yes
Yes
Unlimited
-20 °C to +90 °C
Interior rooms, outdoors, in
water, in the ground and in
installation ducts
190 mm
60 mm
47 mm
12 mm - 18 mm
min.
3 x 2.5 mm²
max.
5 x 6 mm²
235 mm
69 mm
49 mm
14 mm - 21 mm
min.
3 x 4 mm²
max.
5 x 10 mm²
310 mm
88 mm
60 mm
20 mm - 30 mm
min.
3 x 10 mm²
max.
5 x 25 mm²
11