Coldmachine
11
Disposal
➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
12
Troubleshooting
LED on the thermal element (fig. 1 2, page 3)
Number of
Error type
flashes
1
Battery protection shutdown
2
Fan overvoltage shutdown
3
Compressor start-up fault
4
Compressor overload shutdown
5
Electronic fuse shutdown
EN
Remedy
Check battery voltage, fuse and cable
cross section
Check condenser and vaporiser fan
current:
total target value < 0.5 A
Reduce load on cooling system:
• Ensure good ventilation around the
cooling unit
• Store pre-cooled goods
Reduce load on cooling system:
• Ensure good ventilation around the
cooling unit
• Store pre-cooled goods
Reduce load on cooling system:
• Ensure good ventilation around the
cooling unit
Disposal