Store used CORECEM
Do not pull back on the plunger after dispensing. This may cause plugging of the syringe.
Working time in the self-cured mode (23°C (74°F)): 1:30 minutes from start of mixing.
Setting time in the self-cured mode (23°C (74°F)): 5:30 minutes from start of mixing.
-syringe with fixed used mixing cannula in the dark.
®
POST CEMENTATION
Prepare the post space according to manufacturer's
instructions. Etching and Primer are required.
Dispense a small amount 2-3mm to eliminate the pre-
vious mixing and voids.
Apply CORECEM
canal tip (recommended). Filling should occur from
bottom upward to prevent voids.
Seat the post, light-cure for at least 20s. (400mW/cm²)
CORE BUILD-UP
Fill in CORECEM
fill in directly into the preparation. Filling should occur
from bottom upward to prevent voids
Light-cure for at least 40s 400mw/cm² or allow the sys-
tem to self-cure for at least 3 minutes
Remove the matrix when the material is completely
set.
Start the final crown preparation.
CORECEM
For
during trimming. After finishing, blue color will become
dentin shade like A1.
inside the root canal using the root
®
into the COREFORM
®
ILLUSION
®
use cold water spray
matrix or