Bell W_e
Your garage door opener is programmed with
self-diagnostic capabilities. The "Learn" button!diagnostic
LED will flash a number of times then pause signifying it
has found a potential issue. Consult Diagnostic Chart below.
Diagnostic
Chart
Safety
reversing
sensors
wire open (broken
or
disconnected).
OR
Safety
reversing
sensors
wire shorted
or
black/white
wire
reversed,
®
Door control
or
wire shorted.
0
Safety reversing
sensors
slightly
misaligned
(dim or flashing
LED).
Motor overheated
or
possible
RPM sensor
failure.
Unplug
to reset.
Motor Circuit Failure,
Replace
Receiver
Logic Board.
Symptom:
One or both
of the Indicator
lights
on the safety
sensors
do
not glow
steady.
- Inspect sensor wires for a short (staple in wire), correct wiring polarity
(blackJwhite
wires reversed),
broken or disconnected
wires, replace/attach
as needed.
• Disconnect
all wires from back of motor unit
- Remove sensors from brackets
and shoden sensor wires to 1-2 ft
(30-60 cm) from back each of sensor
- Reattach sending
eye to motor unit using shortened
wires
If sending
eye
indicator light glows steadily, attach the receiving
eye.
• Align sensors,
if the indicator
lights glow replace the wires for the sensors.
If the sensor indicator
lights do not light, replace the safety sensors.
Symptom: LED is not lit on door control.
- inspect door control/wires for a short (staple in wire), replace as needed.
. Disconnect wires at door control, touch wires together If motor unit
activates, replace door control
= If motor unit does not activate, disconnect door control wires from motor
unit Momentarily short across red and white terminals with jumper wire.
If motor unit activates, replace door control wires.
Symptom:
Sending
indicator
light glows steadily, receiving
indicator
light is dim or flashing.
• Realign receiving
eye sensor, clean lens and secure brackets
• Verify door track is firmIy secured
to wall and does not move.
Symptom:
Motor has overheated;
the motor unit does not operate or
trolley is stuck on stop bolt = Motor unit hums briefly;
RPM Sensor =
Short travel 6_8" (15_20 cm),
- Unplug unit to reset Try to operate motor unit, check diagnostic
code.
- If it is still flashing
5 times and motor unit moves 6-8" (15-20 cm), replace
RPM sensor.
. If motor unit does not operate,
motor unit is overheated..
Wait 30 minutes
and retry.. If motor unit still wil! not operate
repIace logic board
Symptom:
Motor unit does not operate.
. Replace
logic board because
motor rarely fails.
34