Clear Records; Battery Replacement - TFA Dostmann RAINMAN Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
TFA_No. 47.3004_Anleitung_07_20
14.07.2020
RAINMAN – Wireless rain station with indoor/outdoor temperature
8.2 24 hours rain alert
• Press the RAIN ALARM button in normal mode, to enter the rain alert mode.
• ALERT and 12.7 (default) or the last adjusted alert value appear on the display.
• Press and hold the RAIN ALARM button.
• The alert value flashes and the alert symbol appears on the display. The alert is activated.
• Press the CLEAR/UP or DOWN button to adjust the alarm value.
• Confirm the setting with the RAIN ALARM button.
• If a selected alarm limit is passed, an alarm signal will sound for 5 seconds at the base station. The alarm
symbol flashes.
• The alarm tone will sound again for 5 seconds in every minute.
• Press any button and the alarm will stop.
8.2.1 Activate/deactivate the rain alert
• Press the RAIN ALARM button in alarm mode, to activate or deactivate the alarm function.
• The alarm symbol appears/disappears.
8.3 History mode
• Press the CLEAR/UP button in normal mode, to enter the history mode.
• DAYS AGO 1, the last day date and rainfall amount appear on the display.
• The instrument stores the values of 365 days. Press CLEAR/UP button again to scroll back the rain history
(DAYS AGO) of day 2 - 365.
• To search for a certain date, press and hold the CLEAR/UP button in history mode for three seconds.
• The year indication flashes.
• Press the CLEAR/UP or DOWN button to adjust the year.
• Confirm the setting with the SET button and set the month in the same way.
• Press the SET button again to adjust the day in the same way.
• Confirm the setting with the SET button.
• The value for the chosen date appears.
• The device will automatically quit the history mode if no button is pressed for 20 seconds.

8.3.1 Clear records

• Remove the batteries from the base station.
• Insert the batteries again, polarity as illustrated.
• Press the CLEAR/UP and DOWN button at the same time.
• All recorded values will be cleared.
9. Alarm clock function
• Press the SNOOZE/AL button in normal mode, to enter the alarm mode.
• ALM and 0:00 or the last adjusted alarm time appear on the display.
• Press and hold the SNOOZE/AL button.
• The alarm symbol will appear and the hour digit will be flashing. The alarm is activated.
20
10:05 Uhr
Seite 11
RAINMAN – Wireless rain station with indoor/outdoor temperature
• Press the CLEAR/UP or DOWN button to adjust the hours.
• Confirm the setting with the SNOOZE/AL button and set minutes in the same way.
• Press the SNOOZE/AL button again.
• The current time and the alarm symbol appear on the display.
• When the adjusted alarm time is reached, the alarm rings.
• The alarm symbol flashes.
• If the alarm is not stopped manually, the ascending alarm tone automatically turns off after two minutes and
the alarm will be reactivated at the same set time on the following day.
• Press any button (except SNOOZE/AL) and the alarm will stop.
• Press the SNOOZE/AL button to activate the snooze function.
• Once the snooze function is activated, the alarm symbol will be flashing on the display.
• The alarm will be interrupted for 10 minutes.
9.1 Activate/deactivate alarm clock
• To activate/deactivate the alarm function, press the SNOOZE/AL button.
• The alarm symbol appears/disappears.
10. Positioning of base station and transmitters
• Place the rain sensor horizontally in an area where rain can fall directly into the container, ideally 60 to 90 cm
above the ground on a small platform.
• Choose a shady and dry place for the temperature transmitter. Direct sunlight may trigger incorrect measure-
ment and continuous humidity damages the electronic components needlessly.
• Place the base station in any room of the house. Avoid the vicinity of any source of interference such as com-
puter screens, TV sets or solid metal objects.
• Once the desired location is chosen, check whether the transmission from transmitters to the base station is
possible (transmission range of up to 100 m in open areas). Within solid walls, especially with metal parts,
the transmission range can be reduced considerably.
• If necessary choose another position for the transmitters and/or base station.
• Is the transmission successfully, you can wall mount the temperature transmitter or place it onto a flat surface.
• Insert two mounting screws through the holes in the base of the rain sensor.
11. Care and maintenance
• Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
• The rain gauge is prone to blockages due to its funnel shape. Check and clean the rain gauge periodically for
optimum performance of the rainfall measurement.
• Remove the batteries from all instruments if you do not use the products for a long period of time.
• Keep the devices in a dry place.

11.1 Battery replacement

• Change the batteries of the rain sensor, when the battery symbol appears on the rain quantities display.
• Change the batteries of the outdoor transmitter, when the battery symbol appears on the outdoor temperature
display.
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

47.3004.01

Tabla de contenido