Installation (continued)

PLACEMENT

Position the cabinet in the intended location . If required, level the cabinet by adjusting the four leveling legs and checking the alignment of the top
using a carpenter's level .

DRAINAGE

The tailpipe (not supplied) previously installed to the drain can now be connected to your household plumbing . In some cases, your household
plumbing will have to be modified to ensure proper drainage. If so, please consult a licensed plumber to complete
needed modifications.
SUPPLY LINES (NOT INCLUDED)
Connect the supply lines to your home's water supply as per manufacturer's instructions .
Open the hot and cold water supply valves and check to make sure they have
been installed to appropriate inlet ports . Check for leaks . Run hot and cold water
uninterrupted for about one minute to remove any residue from the lines .

Maintenance

CARTRIDGE REPLACEMENT

-
Turn off the water supply to the faucet .
-
Remove the setscrew cap . Loosen the setscrew with the hex
key provided and remove the handle .
-
Gently unscrew the decorative cap by hand . Use a wrench to
unscrew the retaining nut .
-
Pull the cartridge out of the faucet body and replace it with a
new ceramic cartridge . Ensure new cartridge is seated properly
with the locating pins in appropriate place .
-
Secure the cartridge in place using the retaining nut .
-
Gently tighten the retaining nut using a wrench .
Do not overtighten .
-
Reinstall the decorative cap . Slide the handle back onto the
lever arm and make sure it rotates freely . Secure the handle in
place using the setscrew and cover it with the setscrew cap .
-
Turn the water supply to the faucet back on .
-
Operate the faucet to make sure everything works correctly .
QL107
Cartridge
Faucet body
10
Retaining Nut
Decorative Cap
Handle
Setscrew
Setscrew Cap