� EASY PROGRAMMING
IMPORTANT! it is imperative that the keypad should be connected to its remote
electronics.
• PROGRAM A MASTER CODE : The code of origine is 0 0 0
Key in 0 0 0 then P The yellow light comes on
Press 0 and 0 0 0 Key in the new master code (1 to 8 digits)
Example 5823 : Press 0 and 0 0 0 Key in 5 8 2 3 then A and P
The yellow light goes off
• ENTER PROGRAMMING MODE
Just key in your new master code 5 8 2 3 and P
The yellow light comes on
• PROGRAM USER CODES FROM 001 TO 250
° 001 : Press 0 then 0 0 1 Key in the code (1 to 8 digits)
code n
Example 18126 : Press 0 and 0 0 1 then 1 8 1 2 6 and A
° 151 : Press 0 and 1 5 1 key in the code (1 to 8 digits)
code n
Example 057558 : Press 0 and 1 5 1 then 0 5 7 5 5 8 and A
• PROGRAM THE PUSH-BUTTON TIME (001 TO 240 SECONDS) OR IN
OPERATION/STOP
Example of push-button time of 6 seconds relay 1: Press 1 then 0 0 6 and A
Example of operation/Stop relay 2: Press 2 then 0 0 0 and A
Codes 001-150 to oUTpUT 1 - Codes 151-250 to oUTpUT 2
ERASE THE SERVICE CODES
°3 : Composez 9 puis 0 0 3 et A
erase code n
: Press 9 then 2 5 5 (BEEEP) and A
erase all codes except the master code
: Press 9 then 0 0 0 and A
erase master code
• PROGRAM ILUMINATION
Automatic light
Permanent light
Key ø : Codes programming
key 1 : Relay 1 tempo
key 2 : Relay 2 tempo
key 5 : Ilumination, access control
press (p) To eXiT programmiNg
The yeLLoW LighT goes off
EMERGENCY PROCEDURE
IF YOU LOSE OR FORGET YOUR MASTER CODE, THIS OPERATION ALLOWS YOU
TO ENTER THE PROGRAM AND INPUT A NEW ONE :
1) Disconnect the power supply and wait 5 seconds,
2) Put the programming bridge in the low position P,
3) Reconnect the power supply
4) Put the programming bridge in the high position N,
the yellow light comes on,
5) Press key P, the yellow light comes on,
6) Press key 0 then 0 0 0 ,
7) Key in the master code you want, (1 to 8 digits)
8) Validate the operation with key A
9) Press key P to exit programming
� DIARY USE
: 18126 : Press 1 8 1 2 6 and A
your code
OUTPUT 1 is activated for 6 seconds
: 057558 : Press 0 5 7 5 5 8 and A
your code
OUTPUT 2 is deactivated when you key in your code again
and validate the operation with A
• PUSH-BUTTON
Pressing push-button activates relay 1. Connect the BP and C entries.
� ELECTRO-LOCK CONNECTION
To program special functions (access control, alarm and automation), first, you
EASY PROGRAMMING have to enter in the programming mode. (Refer to point 3)
DIRECT CURRENT
NO C NC
Diode BY 251
Electro-lock
5 000 A
5 001 A
Key 6 : Door management
Key 8 : Alarm or automation
Key 9 : Code erasement
ALTERNATE CURRENT
NO C NC
-
Varistor of correct voltage
+
Electro-lock
ACCESS CONTROL FUNCTIONS
Maximum door opening time:
If the door is still opened when the relay tempo is over, the second relay is activated.
Wire a door detector between input GT and C.
• Program your door detector input (GT)- Detection when contact is opened.
Max. 2400 seconds
Door Break in input: when the door is broken in, the second relay is activated.
Connect a door contact between GT and C connectors.
Time allocation :
When the clock closes the contact, codes from 001 to 100 are not accepted.
Wire a clock between input I and C.
Free access with key P : (with external clock)
When the clock closes the contact, key in P activate relay 1 (door). Wire the contact of
the clock between input I and C.
Maximum door opening time mode (ex : 140 sec.)
Door break in mode
Hour control and automatic ilumination mode
Hour control and permanent ilumination mode
Free access and automatic ilumination mode
Free access and permanent ilumination mode
� ALARM FUNCTIONS
Press 8 then 000 and A to cancel the modes
Self-protection mode : Relay 2 activates when keypad is teared off.
Security mode : after 8 incorrect codes, relay 2 activates
Twin mode : Codes from 001 to 150 activate relay 1 (open a door) and deactivate
the relay 2 (alarm off ). Once the relay 2 is off, those codes are still operating to open
but do not change the second relay status. To RE activate the relay 2, just you have
to use codes from 151 to 250.
Accelerated mode : To deactivate relay 2, press the 2 first digits of the codes from
151 to 250. To activate relay 2, you have to press the complete codes.
Self-protection mode
Security mode
Twin mode
Accelerated mode
It is possible to combine several modes regarding the needs of the installation.
Self-protection and security mode
Self-protection, security and accelerated mode
Panic code : In the following example, OUTPUT 2 is used as a PANIC of OUTPUT 1.
The code 157558 is the panic code.
OUTPUT 1 : code 001 ... 057 558
OUTPUT 1 : code 002 ... 157 558
OUTPUT 2 : code 151 ... 157 558
The aCCess CoNTroL aNd aLarm modes are NoT CompaTibLes
� AUTOMATION FUNCTIONS
Press 8 then 000 and A to cancel the modes
To enter those modes, enter a user code then key in A. The yellow light flashes and the
buzzer emits a signal. To exit those modes, key in P.
Manual mode :
Allows to move an automation in one way when key 4 is pressed.
Pressing key 6 moves the automation in the opposite direction.
Automatic mode :
Allows to move an automation in one way impulsing the key 4 until
the realy tempo is over or until you key in A, O or P. Key 6 moves in the opposite
direction. Key O stops the automation. Key 4 relay 1/ key 6 relay 2/ key O stops relay.
Manual mode
~
Automatic mode
~
6 014 A
6 000 A
5 010 A
5 011 A
5 000 A
5 001 A
8 100 A
8 010 A
8 003 A
8 004 A
8 110 A
Examples
8 114 A
8 001 A
8 002 A