Program Mode
In this mode, the ambient temperature is maintained at the comfort level or at the Nightly level according to time slots
programmed as desired by the user.
1. Press the [mode] key until the corresponding icon appears on the display.
2. Press [Clock] key to choose P1, P2, P3 programs.
Note: To modify pre-set programs P1, P2 or P3, see 3.5 Programming.
3.4. ADVANCE FUNCTIONS
Keyboard Lock
It is possible to lock the device to the "On / Stand-by" key to avoid improper or involuntary use, such as protecting children or
in a public space.
To turn on / off the keypad, press the [mode] key for 5 seconds. Keyboard lock icon is displayed.
Timer 2h
The "Timer 2h"mode can be used to quickly warm up the room or to speed up.
2. Press the [Mode] key until the display shows the "2h" icon.
The device is activated at the maximum power for 2 hours, up to a maximum radiator temperature. The "Timer-2h" mode is
automatically deactivated after a period of 2 hours returning to program mode. The user can switch to another operative mode
at any time by simply pressing the [Mode] key.
Adaptive Start Control
This function, if activated, will turn on the radiator in advance of the programmed (Max 2 hours) to ensure that the room has
reached the desired temperature at the set time.
Note: The function takes at least a couple of days to reach maximum efficiency.
Open Window Detection
The "Open Window Detection" function enables detecting of an open window by sensing a sudden decrease of the
temperature in the room. In such a case, the device deactivates the heating element for a maximum of 30 minutes until at which
point the radiator will resume to operate in the previously set state.
When this function is enabled, the "Open Window" icon is shown on the display. When the device detects that the window is
potentially opened, the "Open Window" icon starts blinking. When the function is disabled the "Open Window" icon is not
shown on the display.
3.5. PROGRAMMING
Day and time setting
1. Activate "Stand-by" mode and press the [clock] key for more than 5 seconds to enter configuration menu.
2. With the [+] and [-] keys, scroll through the menu to the Time function, press [mode] to confirm.
3. Day: The word "day" blinks for 2 seconds, with the [+] and [-] keys select the Day and confirm with the [mode] key.
4. Hour: Use the [+] and [-] keys to select the time and confirm with the [mode] key.
5. Minutes: Use the [+] and [-] keys to select the minutes and confirm with the [mode] key. When finished, the device
will exit the programming menu.
Program setting
Pre-set programming P1, P2 y P3 used in program mode can be modified by the user.
1.
Activate the "Program" mode using the [mode] key. Press the [Clock] key to choose which of the programs P1, P2, P3
to set.
2. Hold the [Clock] key to set the time sequence.
3. Now a time sequence can be set for each day of the week. It starts with day 1, the time zone is displayed, the desired
sequence is selected with [+] and [-] keys. For each hour, the "Comfort" temperature (2 displayed bars) can be set by
pressing [+] key and the "Night" temperature (1 displayed bar) can be set by pressing [-].
4. Press [Mode] to confirm the first day setting and enter next day programming.
5. Repeat the same procedure for the remaining 6 days of the week.