Read this entire installation manual to ensure proper installation. When finished with the installation,
file this manual with the owner or maintenance department. Compliance and conformity to local
Installation
codes and ordinances is the responsibility of the installer. Rough in the shower according to the
instructions provided with your shower.
The maximum temperature for this valve has been set to approximately 110°F (43°C) with an
incoming hot water temperature of 140°F (60°C). This maximum temperature may need to be adjusted
based on the installation conditions or application. The maximum inlet temperature of the valve is
180°F (82°C), with a recommended inlet temperature of 120°F - 180°F (49°C-82°C). The valve has a
maximum operating pressure of 125 PSI (860 kPA). Water temperature over 110° may result in serious
scalding. Excessive heat to the valve may cause damage to internal parts.
Separate parts from packaging and make sure all parts are accounted for before discarding
Packing List
packaging material. If any parts are missing, do not begin installation until you obtain the missing
IS
T H
E
S ID
U P
parts.
Make sure that all water supply lines have been flushed and then completely turned off before
beginning installation. Debris in supply lines can cause valves to malfunction.
Product warranties may be found under "Products" on our web site at

Supplies Required

• Teflon Tape
• 3/32" and 1/8" Allen Key Wrenches
• Screwdriver
• 1/2" NPT Brass Pipe Plug