SOMFY animeo Connect IP/io Guia De Instalacion página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
EN
A
MOUNTING
[1] Wall mounted version
⚠ The device must not be mounted in an electrical cabinet
⚠ Do not cross cables over the product!
B
WIRING
[1] Wiring diagram
A. IP Bus (input/output)
The cable used for the IP Ethernet connection must be a shielded cable.
The shield needs to be connected on both ends.
Not compatible with PoE switch.
n
B. 7 minutes after switching on the device, the green flashing LED indicates normal operation.
[2] Topology
C
COMMISSIONING AND OPERATING
Complete installation of all devices.
Connect the PC to the IP input.
Run the animeo Connect Operating Software and follow the procedure described in the software guide.
CHARACTERISTICS
Supply voltage
Power Supply
Minimum current
Max. current
Minimum power
Radio frequency
Radio range
Operating temperature
Relative humidity
Material of housing
Housing dimensions (w x h x d)
Protection class
Degree of protection
Pollution degree
Conformity
CABLE
Connection to ...
Power Supply
Ethernet
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
24 V DC +/- 10 % SELV/1 A max.
Mandatory use of certified power supply with limited power (certified according to the relevant version of
60950-1 or 62368-1, EN/IEC or UL as needed in the country of use).
Limited power classified as LPS, PS2 or UL class II (according to standard).
32 mA
40 mA@24 V
0.74 W
868 MHz
min. 200 m in open field
0 ° C ... + 50 ° C
85 % at 30 ° C
ABS
133 x 86 x 44 mm
IP20
2
www.somfy.com/ce
Cable
Cat. 6
Twisted pair
Max. length
1.8 m
100 m
animeo Connect . IP/io Gateway . Ref. 5137982C -