General Specifications

Display: 3 3/4 Digit LCD, max. reading of 3999.
Polarity indication: automatic, "–" indicated; "+" implied.
Overrange Indication : "OL" or "– OL".
Range selection: automatic; Measuring Rate: 2/sec, nominal.
Position Error: ±1% of Reading.
Type of Sensing: Hall effect sensing for AC and DC.
Low Battery Indication:
Auto Power Off: approx. 30 minutes after power on.

Environmental Conditions

Operating Temperature: 0 °C to +50 °C, <75% R.H.
Storage Temperature: -20 °C to +60 °C, <80% R.H., battery removed.
Temperature Coefficient: 0.2 x (Spec.Acc'y) / °C, < 18 °C or > 28 °C.
Power Requirement: Single 9V PP3 battery (NEDA 1604,1EC 6F22)
Battery Life: Alkaline 40 hours typical.
Max / Conductor Size: 51 mm diameter or 24 x 60mm busbar.
Size (LxWxD): 240x106x40mm (9.5"x4.2"x1.6"); Weight: 420grams (14.8oz)
Accessories: Battery (installed), manual and carrying case.
Safety: Meets EN61010-1 Cat III 1000V; EMC: Meets EN50081-1, EN50082-1
EMC: This product complies with requirements of the following European
Community Directives: 89/336/EEC (Electromagnetic Compatibility) and
73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE Marking).
However, electrical noise or intense electromagnetic fields in the vicinity of the equip-
ment may disturb the measurement circuit. Measuring instruments will also respond
to unwanted signals that may be present within the measurement circuit. Users
should exercise care and take appropriate precautions to avoid misleading results
when making measurements in the presence of electronic interference.

2-3 Electrical Specifications

Accuracy is ±(%reading + number of digits) at 23 °C ±5 °C, < 75% R.H.
Overload Protection, all functions and ranges: 2000A AC/DC for 1 minute.
DC Current (autoranging)
Range
0 to 100A
100A to 400A
400A to 1000A
AC Current (40 - 400Hz; autoranging)
Range
0 to 40A
40A to 400A
400A to 1000A
AC Conversion Type: AC conversions are ac-coupled, true rms responding,
calibrated to the rms value of a sine wave input. Accuracies are given for sine

SPECIFICATIONS

.
Resolution
0.1A
0.1A
1A
Resolution
0.1A
0.1A
1A
– 10 –
Accuracy:
±(2.9%rdg + 8dgt)
±(1.9%rdg + 5dgt)
±(2.9%rdg + 5dgt)
Accuracy:
±(1.9%rdg + 8dgt)
±(1.9%rdg + 7dgt)
±(2.9%rdg + 5dgt)