3
3.1
WARNINGS
The installation and electrical connection of the air conditioner should be carried out by specialized personnel who
possess the requisites set forth by law. The installation instructions are contained in the appropriate paragraph of this
manual.
No structural object (furniture, curtains, plants, leaves, blinds, etc.) should ever obstruct the normal flow of air from either
the internal or external gratings.
Never lean or, worse yet, sit on the casing of the air conditioner as this could cause serious damage to the external parts.
Do not move the horizontal air outlet fin manually. Always use the remote control to adjust baffle position.
If the unit leaks water, switch it off immediately and disconnect it from the power mains. Call the nearest service centre.
When the air conditioner is heating, it has to periodically eliminate any ice that could form on the external battery. While
it is doing this, the machine keeps running but does not heat the room. This lasts for a brief period of time, from 3 to a
maximum of 10 minutes.
The air conditioner must not be installed in rooms where explosive gasses develop or where there are conditions of heat
and humidity beyond the maximum limits indicated in the installation manual.
Clean the UNICO BOILER MASTER air filter periodically, as described in the specific paragraph.
3.1.1
Components of the system (fig. 41)
The system is made up of a UNICO BOILER WALL unit (1) and a UNICO BOILER MASTER unit (8) containing the compressor,
the fan, the heat exchanger and the remote control (9) for management and control of the various functions (see sect. 3.3.2).
Other information:
2
Air intake
The air in the room is drawn in, and passes through the filters that trap the dust.
3
Air outlet
The treated air is released through the bottom grating.
4
Cooling gas pipes
The outside and inside units are connected by copper pipes through which the cooling gas circulates.
5
Communication cable.
3.1.2
Description of the warning panel of UNICO BOILER MASTER (fig. 24)
G)
Transparent area in which the signal is received from the remote control.
LED D) Green LED that indicates the machine is running (when the machine is in standby this light is off).
LED C) Yellow LED signals activation of the programming switch on and/or switch off.
LED B) Green LED that indicates the switching on of the cooling compressor.
LED A) Red LED that indicates the air filter may need cleaning.
H)
Micro key only on unit.
3.1.3
Description of the UNICO BOILER WALL control console (fig. 43)
L2
When the red LED comes on, it signals that water is being heated up (if it is flashing it means that the heating function is taking place
through the BACKUP function)
STANDBY
On/Off button
TURBO
button for selecting TURBO1 or TURBO2 or neither function
ECO
button for selecting the water temperature setting (two different setpoint values can be memorised, one normal and
one ECO
+
button for increasing the temperature setting
-
button for decreasing the temperature setting
3.2
MANAGEMENT OF UNICO BOILER MASTER WITH REMOTE CONTROL
3.2.1
Remote control
The remote control supplied with the air conditioner is designed to be extremely sturdy and to ensure excellent performance in
use, but it should nevertheless be handled with some care.
For example, do not:
-
leave it out in the rain, spill water on its keyboard or drop it into water
-
subject it to impacts or drop it onto hard surfaces
-
leave it exposed to direct sunlight
-
place obstacles between the remote control and the air conditioner while using it.
Furthermore:
-
if other devices operated by remote control (TV, radio, stereo systems, etc.) are located in the same room as the air conditioner,
there may be interference,
USE AND MAINTENANCE (user part)
3
49
UNICO BOILER