ECO - ECP MANUAL
ENGLISH
MAINTENANCE
-) To insert exciter rotor, use a suitable puller, which can be easily
constructed or forwarded by the manufacturer upon request.
f)
Replacement of voltage regulator
All generators are equipped with an automatic voltage regulator;
depending on the alternator model, electronic regulators can be of
two different types: SR7/2-G, UVR6/1-F.
The SR7/2-G is an integral part of the 28-31-32-34 generators; the
UVR6/1-F is supplied with the 38-40-43 and 46 versions. Should
some anomalous functioning be detected, please consult our
technical manual or contact our technical assistance service.
Once it has been ascertained that the regulator needs to be
replaced, proceed as follows :
-) Disconnect all terminal board wires
-) Unscrew the 2/4 clamp screws of the regulator
-) Set new regulator in the usual position
-) Tighten the new regulator with the previously unscrewed screws
-) Connect again all wires to the terminal board of the regulator.
Follow diagrams supplied by Mecc Alte, if necessary.
24
ECO-ECP iMANUAL December 2013 Rev. 03