Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
GB
IRL

Technical data

Type of device
Max. filling amount
Max. spraying pressure
Max. operating temperature
Weight when empty / Gross weight max.
Material of tank
Spray wand
Where device is carried
Technical residual quantity
Max. volume flow
Recoil force
Table 1
Assembly
1. Fasten the carrying strap [6] on the tank [1] (Fig. 2)
2. Push the hose [3] with the discharge filter [21] into the tank and secure it with the cap
nut [8]. (Fig. 3)
3. Push the tube [3] into the shut-off valve [5] and secure it with the cap nut [8]. (Fig. 3)
4. Screw the spray wand [7] onto the shut-off valve [5] (Fig. 3)
5. Adjust the length of the spray wand [7] as required. (Fig. 4)
Checks
Visual inspection: Are tank [1], pump [2], hose [3], shut-off valve [5] and spray wand [7]
with nozzle undamaged? (Fig. 1, 3, 4)
+
Pay special attention to the connections between the tank – hose and the hose –
shut-off valve and to the condition of the pump threading and spray wand.
No leaks:
Pump up the empty device to 2 bar (Fig. 11).
► The pressure must not decrease more than 0.5 bar within 30 minutes.
Function:
Pull up the piston pressure gauge [9] (Fig. 5)
► The pressure must dissipate.
Activate the shut-off valve [5] (Fig. 13)
► The shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by
our customer service department or by service partners authorized by us.
Making preparations
Observe the instructions in the section entitled „Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
AUS
USA
15
NZ
CDN
VERIS 3237
5 l (1.32 gal)
3 bar (44 psi)
30 °C (78°F)
1.6 kg (3.53 lbs)/ 6.6 kg (14.55 lbs)
polyethylene
plastic, extendable 52 - 90 cm
on the side
< 0.04 l
0.69 l/min
< 5 N
IND

Publicidad

Tabla de contenido
loading

Tabla de contenido