Honeywell AMH-10000E Instrucciones De Funcionamiento página 6

Aire acondicionado portátil
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
ENGLISH
the lugs on the exhaust nozzle connector are engaged with the
grooves on the connector of unit (Fig. ).
3. Attach the exhaust nozzle (9) to the exhaust nozzle connector (10).
4. Extend the exhaust hose (11) and close the window as far as
possible trapping the exhaust nozzle (9)
INSTALLATION INSTRUCTIONS
Air Conditioning with Installation
If required your appliance can also be installed semi-permanently
(Fig. 5).
Proceed as follows:
1. Drill a hole in an outside wall, through a door or a window pane.
The hole should be no larger than 15mm, and between 35cm and
100cm from floor level. If you drill through a wall, we recommend
that you insulate that section with suitable materials. (Figs. 6-7)
. Fit the flange accessory fixture (1) provided into the hole.
3. Fit the exhaust hose in the housing at the back of the appliance
(Fig. ).
4. Insert the other end of the exhaust hose to the flange already
placed in the hole (Fig. 7).
NOTE: When installing the air conditioner semi-permanently, you
should leave a door slightly open (as little as 1cm) to guarantee
sufficient ventilation.
OPEREATING INSTRUCTIONS: CONTROL PANEL
Power Control
The power control turns the unit on and off.
Warning Light
Condensed water may accumulate in the unit. If the internal tank
becomes full, the warning light in the LCD Display will light up and
the unit will not operate until the unit has been drained.
Mode Control
The Mode Control has 3 settings: Cool, Dehumidify, and Fan. The
settings are adjusted with the Mode Control button. A light will
indicate which setting is being used.
1. Cooling Mode
When cool mode is selected, " " will show in the LCD display.
During the cooling mode the air is cooled and hot air is exhausted
to the outside air through the exhaust tube. Adjust fan speed and
temperature to suit your desired comfort level.
Note : The air exchange hoses must vent outside the room when
using Cooling Mode.
2. Dehumidify Mode
When dehumidify mode is selected, " " will show in the LCD
display. Air is dehumidified as it passes through the air conditioner
without being in full cooling mode. If the room temperature is
>5°C (77°F), fan speed can be adjusted; otherwise, fan speed is
set at Medium.
Note : The warm air exchange hoses must vent inside the
room when using Dehumidify Mode, not outside as it does
when cooling. If the unit is vented outside some cooling
will occur.
6
3. Fan Mode
When fan mode is selected, , or
display. Air is circulated throughout the room with no cooling.
Note: Unit does not need to be vented in Fan Mode.
Fan Speed Control
The Fan Speed Control has 3 settings: High;
Medium; and Low.
Time Setting
Auto Shut Off: With machine in running mode, press the timer
button. Press " +" or " -" to select number of hours you would like
the unit to run before it automatically shuts off.
Auto Turn On: With machine in stand-by mode, press the timer
button. Press " +" or " -" to select number of hours before the unit
automatically starts running in air conditioning mode.
NOTE: Time is adjustable between 1-24 hours.
Temperature Controls
• The temperature control buttons are used for adjusting the
thermostat.
• The default LCD display is the room temperature.
• In cooling mode, when " +" or " -" is pressed the set temperature
is displayed and may be adjusted. After 15 seconds the display will
revert back to showing the room temperature. Temperature is only
adjustable in cool mode.
NOTE: By pressing both the "+" and "-" buttons at the
same time for more than 3 seconds, the display will toggle
between Celsius and Fahrenheit.
OPERATING INSTRUCTIONS: REMOTE Control
The functions work the same a your air conditioner's control panel.
All key functions can be accessed from the remote control (Fig. 10).
Power Control: On/Off
Fan Speed Control:
High; Medium; Low
On/Off Timer Control:
In running mode: Auto switch off
In stand-by mode: Auto switch off
Press "
" or "
" button to adjust the time setting in 1 hour
intervals.
Fahrenheit/Celsius Button: toggles between Celsius and
Fahrenheit settings.
LCD Display
Time/Temperature Set Control:
• Used for adjusting the timer and temperature.
• The default display on the control panel is room
temperature
• When "
" or "
" button is pressed in cool mode the set
temperature is displayed and may be adjusted. After 15 seconds
the display will revert back to room temperature.
• Timer setting is available from 1-4 hours by pressing the "
"
"button." button.
Mode Control: Press to change the operating mode, which will
rotate through Cool - Dehumidify - Fan and back to Cool.
will be shown in the LCD
" or

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Amh-12000e

Tabla de contenido