7. IF THE CONVERTER'S FUSE BLOWS

Your power converter is fitted with a fuse, which should not have to be replaced
under normal operating conditions. A blown fuse is usually caused by reverse
polarity or a short circuit within the device or equipment being operated.
If the fuse does blow:
1. Disconnect the device or equipment immediately.
2. Find the source of the problem, and repair it.
3. Install a new 15A fuse. The fuse can be found on the end of the plug on the converter.
4. Do not over-tighten the fuse cap; finger-tight is sufficient.
ATTENTION: Do not install a fuse higher than 15A, as this may damage the converter.
Make sure to correct the cause of the blown fuse before using the converter again.

8. TROUBLESHOOTING

PROBLEM
The RED LED is lit,
or converter does not
function.
9. SPECIFICATIONS
Maximum continuous power ................................................................. 150 Watts
Surge capability (.01 second) ............................................................... 300 Watts
Full load input current ..................................................................................... 15A
Optimum efficiency ........................................................................................ 85%
No load current draw ...................................................................................<0.3A
Output frequency ................................................................................. 60Hz±3Hz
Output wave form ...................................................................Modified sine wave
Output voltage range .....................................................................110V-125V AC
Input voltage range ..................................................................... 10.0V-15.0V DC
Low battery alarm ..........................................................Audible, 10.5V±0.5V DC
Low voltage shutdown ...................................................... Under 10.0V±0.5V DC
High voltage shutdown ....................................................... Over 15.5V±0.5V DC
AC outlet ............................................................................One, NEMA 5-15 USA
USB port ....................................................................................One, 2.0A 5V DC
Overload protection ........................................................................................ Yes
Cable with 12V accessory plug ...................................................................... One
REASON
Poor contact at terminals.
Blown fuse.
Converter shutdown.
• 6 •
SOLUTION
Unplug and reinsert the 12V plug.
See If the Converter's Fuse
Blows section.
See LED Indicator and Shutdown
Protection section.