4 Functions during the dive
4.1 Immersion
If the water contacts are deactivated (->33), switch on XP10 before immersion.
If you have chosen the option "Water contacts off" ("set 1" or Dive.Log), XP10 will turn on with a
delay of up to 1 minute into the dive. This will affect functioning of the computer. Make sure that the
computer is on before starting the dive.
After immersion, starting at a depth of about 0.8m (3ft), all diving functions are monitored, i.e. depth
and dive time displayed, maximum depth stored, saturation of tissues calculated, no-stop time or
decompression prognosis determined, ascent rate controlled and displayed and the correctness of the
decompression procedure supervised.
4.2 Dive time
Dive time
DEPTH
DIVE TIME
NO
NO
NO STOP
DECO
STOP
STOP
F
If a dive lasts longer than 199 minutes the dive time display starts again at 0 minutes.
4.3 Current depth / O
DEPTH
DIVE TIME
NO STOP
CNS O
%
2
S
L
O
W
Current depth
O
% mix
2
Nitrogen loading bar
4.4 Maximum depth / Temperature
DEPTH
DIVE TIME
NO STOP
CNS O
%
2
Max depth
CNS O
%
2
! WARNING
The whole time spent below a depth of 0.8m (3ft) is displayed as dive time
in minutes. The time above 0.8m (3ft) is counted as dive time only if the diver
descends again below 0.8m (3ft) within 5 minutes.
While the dive time is running, the colons on the right of the figures are flashing
in one second intervals. Maximum dive time displayed is 199 minutes.
% mix
2
Current depth is given in 10cm increments in metric setting and 1ft
increments in imperial setting.
At a diving depth of less than 0.8m (3ft) the display shows " – – – ".
F
Depth measurement is based on salt water. Therefore, XP10
shows a slightly (3%) shallower depth than actual when diving in
fresh water. No calculation however is affected.
Maximum depth is only displayed if it exceeds the current depth by more than
1m (3ft) (maximum indicator function). If maximum depth is not displayed,
XP10 shows the temperature.
> Temperature, O
> Temperature
> Max depth
Functions during the dive
The O
% mix is diplayed as long as CNS O
2
no ascent speed is indicated.
mix
2
, Time
, O
mix
2
% = 0 and
2
21