900 Amp Battery Jumper
7� Observe the color of the Reverse Polarity Protection Indicator that is located between
the compressor and work light button�
If the light is RED, DONOTTURNONTHEJUMPERSAFETYSWITCH!
a� Cable clamps need to be reversed�
b� Disconnect the black clamp first then the red clamp�
c� Reconnect and observe the indicator again�
If the light is GREEN, turn on the Jumper Safety Switch�
a� Allow 2-3 minutes of charging time� It is recommended to have a second
person to assist holding the unit securely in place during the rest of the
instructions�
b� Inside the vehicle, turn on the ignition switch and attempt to start the engine�
c� Crank a maximum of three seconds� If the engine does not start, wait three
minutes before the next attempt�
d� After the engine starts, turn off the Jumper Safety Switch�
CAUTION:Excessiveenginecrankingcandamagevehiclestartermotor�Ifthe
engineturns,butfailstostartafterseveralattempts,othertechnicalproblems
mightbeinvolved�Discontinuecrankingtheengineuntiltheotherproblems
havebeendeterminedandcorrected�
8� When finished, stand as far away from the vehicle battery as possible and disconnect
the clamps in reverse sequence to connecting procedure:
For negative grounded systems, first disconnect negative (black) then
positive (red) clamps�
For positive grounded systems, first disconnect positive (red) then negative (black)
clamps�
www�wagan�com
5
by Wagan Tech
®
User's Manual—Read before using this equipment
USING THE AIR COMPRESSOR
WARNING:Checkitemtobeinflatedformanufacturer'srecommendedmaximuminflation
pressure�Avoidoverinflation�Mosttiresareproperlyinflatedbetween24-35PSI�Some
truckandbicycletiresrequire40PSIormore�
To Inflate Tires
1� Remove valve cap from air valve stem� Note: Make sure locking thumb lever is
in up position. If necessary, use valve stem adapter.
2� Insert stem connector to valve stem� Make sure connector is pushed into valve
stem as far as possible�
3� Press down the locking thumb lever to engage�
4� Set the compressor on/off switch (located next to the pressure gauge) to "on" position
by pressing down the section of switch marked "I"� Note: In the event that the tire is
completely flat, raise the vehicle using a recommended jack before inflating the tire.
5� Monitor tire pressure on air pressure gauge� Note: It is recommended to use a separate
air gauge to check the actual inflation pressure. When desired pressure is reached, turn
off compressor, turn the locking thumb lever to up position, and remove stem connector
from valve stem. Also remove valve stem adapter
if applicable.
6� Replace valve cap on valve stem�
To Inflate Plastic Inflatable (balls, air mattresses, rubber rafts, etc.)
1� Check manufacturer's specifications on the item to be inflated for correct
inflation pressure�
2� Remove valve cap cover from valve stem�
3� Insert proper valve stem adapter into stem connector as far as possible and
turn the locking thumb lever to down position�
4� Insert the other end of the valve stem adapter into inflatable air valve stem
as far as possible�
5� Set the compressor on/off switch (located next to the pressure gauge) to "I" position�
6� Monitor air pressure on pressure gauge meter� When desired pressure is reached, turn
off compressor, turn the locking thumb lever to up position, and remove stem connector
from valve stem� Also remove valve stem adapter if applicable� Replace valve cap on
valve stem�
©2012 Wagan Corporation� All Rights Reserved�