16967
Two rocker push buttons and actuator for 1 roller shutter, change-over relay output for cosφ 0.6 2 A 120-230 V~ motor, to complete
with interchangeable 1- or 2-module buttons - 2 modules
Device to be used as a double or single push button, depending on the button. It
can be configured independently from the actuator too. It can be pressed both at
the top and at the bottom.
CHARACTERISTICS.
• Rated supply voltage: BUS 29 V
• Input: 22 mA
• Relay output
• Controllable loads at 120-230 V~:
- resistive loads:
4 A (20.000 cycles)
- motors cos ø 0.6: 2 A (20.000 cycles)
• Button: double or single
• Terminals:
- TP bus
- Change-over relay contacts (C,
,
• Possible functions:
- ON/OFF switch
- roller shutter control
- dimmer control
- activation of 2 scenarios.
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE
THE By-me SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE
CONTROL UNIT.
Configuration must be done with the device without the key to be able to press the
central configuration button.
• Functional blocks: 3 (2 buttons, 1 roller shutter actuator), each functional block
can belong to at most 4 groups.
• Selecting the functional block (configuration): during group creation, when the
control unit requires pressing the device button:
- press the central button;
- within 3 s, press the right-hand button to select the right functional block or the
left-hand button to select the left functional block; the red LED will light up. If
neither button is pressed within approximately 3 s the red LED will light up; in this
case, the selected functional block is the third one, the one for the actuator;
- with the red LED on, the control unit will configure the functional block; at the end
of this operation the red LED will go out.
When the device is not configured, the actuator is controlled by the left-hand
button.
PARAMETERS.
• For the functional blocks related to the two buttons it is possible to set the operat-
ing mode:
- ON/OFF button;
- dimmer control button;
- roller shutter control button;
- scenario control.
• Operation as a dimmer control button:
- pressing the key at the top for less than 0.5 s lights up the load with the dimming
at the saved point;
- pressing the key at the top for more than 0.5 s increases brightness until it is
released;
- pressing the key at the bottom for more than 0.5 s decreases brightness until it
is released;
- pressing the key at the bottom for less than 0.5 s switches off the load.
• Operation as a roller shutter control button:
- pressing the key at the top for more than 0.5 s opens the shutter completely; it
stops when fully open or when briefly pressing the key (either at the top or bot-
tom);
- pressing the key at the bottom for more than 0.5 s closes the shutter completely;
it stops when fully closed or when briefly pressing the key (either at the top or
bottom);
- use only roller shutters with a built-in limit switch.
Viale Vicenza, 14 - 36063 Marostica VI - Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188
Fax (Export) +39 0424 488 709
www.vimar.com
Plana
14527
)
FRONT VIEW.
A
Eikon
Arké
B
A
Idea
Plana
B
Caption:
A: configuration button - B: led
• LED parameters:
- LED off;
- LED with normal operation (on if the associated actuator is ON);
- LED with reverse operation;
- LED always on for location in the dark;
- central LED with normal operation (on if the associated actuator is ON);
- central LED with reverse operation;
- central LED always on for location in the dark
If the functional block belongs to more than one group, the "LED with normal
operation" and "LED with reverse operation" parameters are not available. In
these cases the control is confirmed by a LED status change for 3 s. If a double
key is used, it is necessary to set the central LED behaviour to make the status
visible. In this case, configure the left-hand button only.
• Functional block 3, related to the roller shutter actuator:
- on delay on reception of a scenario command from 0 to 250 s in steps of 1 s;
- on delay on command from 0 to 250 s in steps of 1 s.
- off delay on command from 0 to 250 s in steps of 1 s;
• Default parameters: the two keys are enabled as a shutter control and LED in
normal operation; shutter actuator with null on and off delay.
SCENARIOS.
Each tilt button can be dedicated to activating one or two scenarios. The actuator
can belong to up to 4 different scenarios and, for each scenario, save the status to
retrieve when activating the scenario. The saved status can only be either shutter fully
open or fully closed.
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electri-
cal systems in the country where the products are installed.
The feeding circuit of the relay output must be protected against overloads by a
device, fuse or automatic circuit breaker, with rated current not higher than 16 A. For
further instructions, please see the manual attached to the control panel.
CONFORMITY.
LV directive
EMC directive
Standard EN 50428.
BACK VIEW.
A
B
A
C
terminals
TP bus
B