Always follow all safety precautions
when
cleaning
and servicing
the POWER-MATE
TM.
Electrical
Shock Or Personal Injury
Hazard
Disconnect
electrical
supply before
servicing
or cleaning the unit.
Failure to do so could result in elec-
trical shock or personal
injury from
cleaner suddenly
starting.
1. Remove light
cover by pressing
in and lifting both
sides as shown.
Push In
_
2. Push in and turn
And Turn r_
bulb counterclock-
_
wise to remove.
3. Replace the bulb.
_
Bulb must not be
_"%
higher than 15 Watts.
_---_'_
Close light cover until
it snaps in place.
NOTE: See PARTS AND FEATURES for
Bulb #.
Disconnect
cleaner from electrical
outlet.
Check and remove hair, string and lint build-
up frequently
in the POWER-MATE
TM
brush
and brush support areas. If build-up
becomes excessive, disconnect POWER-
MATE
TM
from wand and follow the steps
below. Instructions can also be found under
the light cover.
TO REMOVE BELT:
1. Remove light
cover and light
bulb as shown
under LIGHT
BULB
CHANGING.
2. Unscrew the
POWER-
MATE
TM
cover
screws.
3. Turn
POWER-
MATE
TM
over.
To remove
cover, insert
screwdriver
at
cover tabs on
both sides and
twist to
release tabs.
14
4. Turn POWER-
MATE
TM
right
side up. Press
handle release
pedal and lower
the swivel. Tilt
Q_lck
cover forward
Re/ease from back until
front snaps free.