6. Connection notes
Warranty
IVT GmbH & Co. KG will exclusively assume warranty for the functionability of
the LATENTO XW only then if all notes described in this chapter are observed.
Heating connection
It is essential to take care of professional bleeding (e.g. automatic bleeder) when
connecting the LATENTO XW to the heat generator/s.
Caution
If there are steel pipes used in the cold water supply or in the
heating grid, beware of the danger of getting steel blades in
the drinking water heat exchanger. This has to be prevented
by using a filter, otherwise there may be a contact corrosion,
causing a permeable drinking water heat exchanger.
6.1 Transportation
The LATENTO XW must always be delivered in a standing
Note
position so as to avoid any damage! The LATENTO XW may be
tilted max. horizontally for a short time, e.g. when carrying it
to the place of installation. Great care must be taken that the
cover was closed with all screws.
25